Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
- 
                     Seismic Design Of Micropile Foundation Systems Seismic Design Of Micropile Foundation SystemsBy Leo Panian Over the last decade, drilled and post-grouted micropile foundations have come to be increasingly relied upon for resisting seismic loads in building foundations on the West Coast. Micropiles have bee Jan 1, 2010 
- 
                     Seismic Hazards Evaluation and Lateral Pile Design in Diatomaceous Earth Seismic Hazards Evaluation and Lateral Pile Design in Diatomaceous EarthBy Arash Khosravifar, Matt Steffan An expansion of the City of Klamath Falls Wastewater Treatment plant required geotechnical seismic hazard evaluations and deep foundation design. The site is located on the shore of Lake Ewauna and is Jan 1, 2018 
- 
                     Seismic Rehabilitation Of Seattle's Pier 69 Seismic Rehabilitation Of Seattle's Pier 69By David Pierce The Port of Seattle, one of the largest on the west coast of North America, made a strong statement regarding their support for reusing existing structures when a decision was made to rehabilitate Pie Jan 1, 1992 
- 
                     Seismic Remediation of Perris Dam Seismic Remediation of Perris DamBy Michael W. Driller, Wen Yan (Grace) Chen, Steven J. Friesen "Remediation for Perris Dam has been proposed in response to deficiencies identified in a seismic stability study prepared by the California Department of Water Resources (DWR) in 2005. Lenses of pote Jan 1, 2015 
- 
                     Seismic Response Of Raft Foundations Supported On Aggregate Piers Seismic Response Of Raft Foundations Supported On Aggregate PiersBy Alper Turan The use of aggregate pier foundation systems has become widespread as the engineering practice moves towards cost-effective ground improvement solutions that provide accelerated construction schedules 
- 
                     Seismic Response of Raft Foundations Supported on Aggregate Piers (f3188351-761b-458f-b00c-1bcc1cb9cf93) Seismic Response of Raft Foundations Supported on Aggregate Piers (f3188351-761b-458f-b00c-1bcc1cb9cf93)By Alper Turan, Hesham El Naggar "The use of aggregate pier foundation systems has become widespread as the engineering practice moves towards cost-effective ground improvement solutions that provide accelerated construction schedule Jan 1, 2017 
- 
                     Seismic Retrofit Of Bridges; Geotechnical Design Considerations And Case History Seismic Retrofit Of Bridges; Geotechnical Design Considerations And Case HistoryBy Aly M. Mohammad State and federal agencies during rehabilitation of existing bridges may require the existing bridges to be evaluated under seismic conditions. If the bridge does not perform under the seismic event, Jan 1, 2006 
- 
                     Seismic Stability Analysis of Seepage Control Measures for Levees in Central Valley, California Seismic Stability Analysis of Seepage Control Measures for Levees in Central Valley, CaliforniaBy Zia Zafir "Levees in the central valley of California are primarily for flood control purposes and thus are subjected to infrequent hydraulic loading. The primary concern for these levees is their instability d Jan 1, 2016 
- 
                     Seismoacoustic Effects Of Driving Large Diameter Piles ? Summary Seismoacoustic Effects Of Driving Large Diameter Piles ? SummaryBy Barry C. Roth Driving of large piles in water can impact marine wildlife. Bubble curtains can mitigate these adverse effects. The procedures for and preliminary results of monitoring airborne, waterborne and ground Jan 1, 2001 
- 
                     Selecting the Right Shoring System – San Francisco Experience Selecting the Right Shoring System – San Francisco ExperienceBy Heinrich Majewski, Rob Jameson "Careful review of site conditions and constraints is essential to select the appropriate shoring system for each project. Key evaluation criteria include the geotechnical profile, groundwater and env Jan 1, 2017 
- 
                     Selection & Design Of Augered Cast-In-Place (ACIP) Piles Selection & Design Of Augered Cast-In-Place (ACIP) PilesBy Dan A. Brown Outline ? Basic Concept of ACIP Piles ? Factors Affecting ACIP Pile Performance ? Applications: - Favorable Conditions - Unfavorable Conditions ? Design for Axial Loading ? Lateral Loa Jan 1, 2004 
- 
                     Selection And Design Of Continuous Flight Auger And Drilled Displacement Piles Selection And Design Of Continuous Flight Auger And Drilled Displacement PilesBy Dan Brown This paper provides an overview of the advantages and limitations of continuous flight auger (CFA) and drilled displacement (DD) systems compared to other deep foundation systems, along with a summary Jan 1, 2005 
- 
                     Selection And Quality Control Of Deep Foundations At Ontario Hydro's Darlington Nuclear Generating Station - Synopsis Selection And Quality Control Of Deep Foundations At Ontario Hydro's Darlington Nuclear Generating Station - SynopsisBy F Debidin The progressive rise of an H-pile during driving of an adjacent pile is described in this case history in which piles 15 to 18 m long were driven to end-bearing for the foundations for a 230 m long bu Jan 1, 2010 
- 
                     Self Drilling Soil Nail Systems To Retain Caving Soils Self Drilling Soil Nail Systems To Retain Caving SoilsBy Ali Porbaha The use of soil nailing technology as a cost effective alternative for excavation support and slope stabilization has substantially increased in the United States during the last decade. For example, Jan 1, 2006 
- 
                     Self Hardening Slurry Wall Installation By Hydromill At The Herbert Hoover Dike ? An Innovative Solution Self Hardening Slurry Wall Installation By Hydromill At The Herbert Hoover Dike ? An Innovative SolutionBy Mario Mauro In 2007 the US Army Corps of Engineers classified the Herbert Hoover Dike in Florida as a Dam Safety Action Classification (DSAC) 1 dam, and started the implementation of one of the largest dam rehabi 
- 
                     Self-Drilling Micropiles Self-Drilling MicropilesBy Matt Sotirin The Santa Fe train station and passenger rail platform were constructed in the downtown district of Fort Madison, Iowa, over a century ago. This landmark building and rail platform were in need of maj Oct 1, 2022 
- 
                     Self-Hardening Slurry Wall Installation by Hydromill at the Herbert Hoover Dike – An Innovative Solution (05e83755-4ec2-4ed4-a26c-d1e81c41960c) Self-Hardening Slurry Wall Installation by Hydromill at the Herbert Hoover Dike – An Innovative Solution (05e83755-4ec2-4ed4-a26c-d1e81c41960c)By Mario Mauro, Jeff Taylor, Carlos Morales "In 2007 the US Army Corps of Engineers classified the Herbert Hoover Dike in Florida as a Dam Safety Action Classification (DSAC) 1 dam, and started the implementation of one of the largest dam rehab Jan 1, 2017 
- 
                     Selmon Expressway, Tampa: Case History of Drilled Shaft Design for Extreme Variability Selmon Expressway, Tampa: Case History of Drilled Shaft Design for Extreme VariabilityBy Ross T. McGillivray, David S. Graham, Dan A. Brown, Steven D. Dapp "The Selmon Expressway includes an elevated structure extending across several miles of weathered karstic limestone geology, and represents a challenge for design because of the high variability of th Jan 1, 2015 
- 
                     Session 10 Deep Mixing Method I Session 10 Deep Mixing Method IBy Peter Cali There is one organization in Sweden, The Swedish Deep Stabilization Research Centre, which has been working with these questions and there is also a project, Eurosoilstab, within European Union to tak Feb 10, 2003 
- 
                     Session 11 Jet Grouting II Session 11 Jet Grouting IIBy George Burke Of the three projects, particularly the extensive Nimitz II (downtown) project, a single system, which was part of the operation, was used to control the spoil. Spoil control was continuous with the w Feb 10, 2003 
