    Installation Of Marine Pile Foundations At The Skyway Project For The San Francisco Oakland Bay Bridge

    By Robb L. Swenson

    Construction of foundations for the Skyway Segment of the San Francisco Oakland Bay Bridge required innovative techniques due to the mass of the structures being inserted and the unique subsurface of

    Jan 1, 2005

  • DFI
    Behavior Of PCC Pile Under Lateral Load

    By Zhitao Ma

    The Cast-in-place Concrete thin-wall Pipe pile, referred to as PCC pile, is a new kind of pile for soft ground improvement. In this paper, firstly, the general introductions of the new pile technique,

    Jan 1, 2006

  • DFI
    Ultimate Uplift Capacity Of Piles And Pile Groups In Granular Soil

    By B. M. Das

    Laboratory model test results for the ultimate uplift capacity of rough rigid single and group piles embedded in sand have been presented. Model tests on single piles were conducted in loose, medium,

    Jan 1, 1989

  • DFI
    Technical Note - Simplified Settlement Model For A Shallow Foundation On Composite Ground With Rigid Piles

    By Timothy C. Siegel

    A piled raft refers to a shallow foundation that is structurally connected to the piles, while composite ground refers to a soil-pile matrix where the piles are not structurally connected. The design

    Jan 1, 2011

  • DFI
    Ground Improvement Design and Construction for Seattle’s Elliott Bay Seawall Replacement and Retrofit

    By Andrew Malinak, William Perkins

    Seattle’s Elliott Bay Seawall protects the 1½ miles of downtown waterfront between South Washington and Broad streets. The seawall supports the urban waterfront and infrastructure, including the Alask

    Jan 1, 2018

  • DFI
    A Contribution To Studies Of Piles Under Dynamic Loads - Synopsis

    By R. J. Folic

    Investigations of the vibrations of a pile in soil are performed on a dynamic model in the form of a prismatic bar of finite axial and flexural stifnesses with a discrete mass at its free end represen

    Jan 1, 2010

  • DFI
    Rapid Vibratory Pile Driving Hammer For Deep Foundation

    By Li Tiemin

    It is one of important tasks in research of vibratory pile driving to increase speed of pile driving and depth of pile driving -- this means to increase capability of penetrating hard layer. In genera

    Jan 1, 1991

  • DFI
    Estimation & Comparison Of Axial Compression Capacity Of Bored Cast In-Situ Piles As Per Indian And International Standards

    By Sowmiyaa. V. S., Tiruvengala Padma

    Axial compression capacities of bored cast in situ piles as per Indian and International Standards are compared in this paper. Bored cast in-situ piles resting on soil and rock are considered for capa

    Sep 1, 2022

  • DFI
    Apportioning Risks On An Urban Deep Foundation Project

    By Michael P. Balducci

    Urban deep foundation projects contain unique risks that must be recognized by the parties involved. Common pitfalls must be recognized and avoided or addressed through contractual relations and corr

    Jan 1, 2008

  • DFI
    Bearing Capacity Of Piles In Soils With Time Dependent Characteristics

    By M. J. Preim

    Two case histories are presented on the evaluation of static bearing capacity of piles driven in soils that exhibit time dependent strength changes. Under consideration are a steel and a concrete pile

    Jan 1, 1989

  • DFI
    Three-Dimensional Stability Analysis Of Vertical Shafts In Homogenous Soils

    By Reza Y. Khaksar

    Presented is a rigorous solution for the three-dimensional stability analysis of vertical shafts (excavations) subjected to the self-weight of the soil based on the upper-bound theorem of limit analys

    Jan 1, 2006

  • DFI
    Non-Destructive Geophysical Evaluation Of Deep-Mixed Soil: A Computer Modeling Study

    By David A. Staab

    Numerical modeling was used to investigate the feasibility of using two geophysical imaging techniques, cross-borehole ground penetrating radar (XBGPR) tomography and electrical resistivity (ER) tomog

    Jan 1, 2004

  • DFI
    Lateral Forces on Pile Due to Soil Slope Creep

    By David E. Albus, Bidjan Ghahreman

    A single-family home constructed on the side of a slope in Los Angeles, CA, was subjected to lateral forces due to soil slope creep on the pile foundation supporting the home. Impacts to the property

    Jan 1, 2018

  • DFI
    Case History: Multiple Axial Statnamic Tests On A Drilled Shaft Embedded In Shale

    By Paul J. Axtell

    Two new railroad bridges in Kansas City, Missouri are founded on drilled shafts embedded into the soil and underlying shale. The uncertainty arising from the non-homogeneous, anisotropic nature of mo

    Jan 1, 2006

  • DFI
    Design Of The Foundation Of Zhu Jiang Fanying High-Rise Building Complex ? Synopsis

    By A. F. Deng

    A general description of the project, mainly the pier foundation design of the ZHU JIANG FANYING is presented in the paper. The major contents include the foundation scheme, the evaluation of bed-rock

    Jan 1, 2010

  • DFI
    Evaluation Of The Group Equivalent Pile Approach For Laterally Loaded Shafts

    By Cheng Lin

    The Group Equivalent Pile (GEP) approach was proposed by researchers to analyze a laterally loaded pile group. This approach enables engineers to evaluate the behavior of a pile group in single pile a

    Jan 1, 2009

  • DFI
    Bearing Capacity Of Nodular Piles

    By S. Kanai

    Nodular piles is to be piles provided with several nodular projections along the pile shaft, as shown in Fig. 1. Nodular piles are usually installed through either driving method with hammer or prebor

    Jan 1, 1989

  • DFI
    Case History: Effect Of Plastic Clays On The Behavior Of APGD Piles In Central Florida

    By Amr M. Sallam

    In recent years, with the increase of the number of high-rise buildings that are proposed and being built in Central Florida especially in Downtown Orlando, Augered Pressure Grouted Displacement (APGD

    Jan 1, 2006

  • DFI
    Construction Of Long Tubular Column Foundations Under Deep Water ? Synopsis

    By C. L. Liao

    The chief experiences for constructing deep tubular columns foundation under deep water are as follows: 1. P.C. tubular columns were sunk inside the caisson. 2. P.O. tubular columns of 3.6 M. diameter

    Jan 1, 2010

  • DFI
    Negative Drag - A Practical Example - Synopsis

    By A. Verghese Chummar

    The paper presents a field study where the effect of negative drag caused the failure of a pile foundation system. Utilising the field observations the probable negative drag that acted on the piles i

    Jan 1, 1996