Search Documents
Search Again
Search Again
Refine Search
Refine Search
-
IC 9073 - Underground Coal Mine Lighting Handbook (In Two Parts) 1. BackgroundBy W. H. Lewis
This Bureau of Mines report and its companion report (Information Circular 9074) have been prepared as a complete reference on underground coal mine lighting. This report discusses the fundamentals of
Jan 1, 1986
-
Factors that May Influence Interactions between Mineral Dusts and Lung CellsBy G. L. Barlett, J .. D. Barry
Supernatant media of dust-exposed pulmonary alveolar macrophages (PAMs) were inactive in assays for both Interleukin-1 and fibroblast growth factors (FGF). We have begun to evaluate several factors th
Jan 1, 1988
-
Introduction (3cf7235d-a887-450c-bdd5-d6383bd539a7)By R. V. Ramani, A. S. C. Owili-eger
The Federal Coal Mine Health and Safety Act of 1969 (sec. 303 (b)) stipulates that no working section of the mine shall contain more than 0.5 percent carbon dioxide and no harmful quantities of other
Jan 1, 1974
-
A Spatial/ Spectral Domain Microwave Coal Seam Imaging Sensor-Progress In Signal ProcessingBy Robert L. Chufo
The paper, "An Electromagnetic Roof and Rib Thickness Sensor" presented at The 12th WVU International Mining Electrotechnology Conference in 1992, presented the results of roof coal thickness measurem
-
Materials And MethodsOnly limited work has been reported in the literature about the use of latex in soil. Unisol 91 2,3 (a 9:l oil-latex emulsion made b International Synthetic Rubber Company) and Phil1ips Petroset4 geo
Jan 1, 1972
-
Abandoned Mine Lands Program TN #2 The Effectiveness Of Surface Seals On Coal Seam Fire Control - ObjectiveDevelop a method to evaluate the effectiveness of coal scam fire surface seals so that potential problems may be corrected at an early stage, before the integrity of the surface seal is lost. Backg
Jan 1, 1991
-
In-Mine Remote Actuated Stench Gas Warning System - ObjectiveProvide an inexpensive, remote actuated, stench-gas system which reduces fire warning time to underground work locations. Approach A mine's pager phone hard-wire network is used to release
Jan 1, 1984
-
IC 7567 Electrical Blasting at Miama Copper Co. Miami, ARIZBy Ernest R. Rodriguez, Allen D. Look
"INTRODUCTION The underground mine of the Miami Copper Co. has operated since 1927 without a fatality from blasting or the handling of explosives. To improve safety and efficiency, electrical blasting
May 1, 1950
-
RI 8604 Electrowinning Nickel and Cobalt From Domestic Laterite Processing - Preliminary Laboratory-Scale ResultsBy R. E. Mussler
As part of an overall goal to develop technology that can maintain an adequate supply of minerals to meet national economic and strategic needs, the Bureau of Mines is evaluating a method for selectiv
Jan 1, 1981
-
RI 6135 Use Of A Large-Diameter Auger In Mining Pitching Anthracite BedsBy J. T. Schimmel
The purpose of this investigation was to obtain complete information on some of the uses of a 24-inch-diameter auger in the underground mining of pitching anthracite beds. The auger was placed in o
Jan 1, 1962
-
RI 5310 Anchorage Testing Of Mine-Roof Bolts - Part 3. Expansion-Type, 5/8-Inch Bolts ? Summary And ConclusionsBy A. J. Barry
Five makes of expansion-type shells and two types of bolts (mild-steel and high-strength) were used in 30 tests made in sandstone and shale roof, The results show that the anchorage obtained in both t
Jan 1, 1957
-
IC 7153 Mine Safety Board Decision 33 (Superseding Mine Safety Board Decision 3) Bureau Of Mines Definition Of A Gassy Coal MineThe Bureau of Mines believes that all coal mines are potentially gassy; for the purpose of administration in the prevention of explosions and fires, the Bureau recommends: That any coal mine wherei
Jan 1, 1941
-
IC 7078 Mine Safety Board Decision 31 - Main Fan Installations At Metal MinesIn the interest of safety in metal mining, the Bureau of Mines recommends: That underground metal mines be equipped with a main fan in a fireproof housing, located preferably on the surface. The fa
Jan 1, 1939
-
RI 4438 Investigation Of Suffern Graphite Deposits Rockland County, N. Y.By W. T. Millar
Graphite in the Suffern deposits near Hillburn, N. Y., consists of flakes ranging in size from fines to one-half inch in diameter. The Bureau of Mines investigated the Suffern deposits in the spring
Jan 1, 1949
-
RI 7030 Nonuniform Radial Loads Applied To The Boundary Of A Circular Hole In An Infinite PlateBy Wilbur I. Duvall
In this report, the Bureau of Mines presents a theoretical solution for the stresses and displacements in an infinite elastic plate containing a circular hole the boundary of which is loaded by applie
Jan 1, 1967
-
Program Installation and OperationBy Rudolf E. Greuer, Linneas W. Laage, Xinton Chang
The program MFIRE consists of four files MFIRE0 EXE, MFIRE1 EXE, MFIRE2 EXE, and MFIRE BAT The batch file, MFIRE BAT, controls the operation and cooperation of the three executable pro¬gram files and
Jan 1, 1990
-
Use of Strain-Gauged Rock Bolts to Measure Rock Mass Strain During Drift DevelopmentBy T. Brady, R. Langston, J. C. Johnson, H. Kirsten
An experiment is described in which instrumented rock bolts were used to measure strain in the rock mass during drift development at the Stillwater Mine, Nye, Montana, USA. Two strain-gauged rock bolt
-
Selected Health Issues In MiningBy R. Larry Grayson, Douglas F. Scott
Data on health-related illnesses and disease in the mining industry are scarce, and information on rates and costs is not readily available. Substantial amounts of research are being directed to addr
-
Complete Hoisting SystemsBy David Hoadley, Kenneth R. Maser, Ashok B. Boghani, James E. Billar, D. Randolph Berry, Mackenzie Burnett, Robert H. Trent
C 2 Complete Hoisting Systems A Above Ground Installations A total of seven companies were identified who supply complete emergency escape hoist units for above ground installations The units ha
Jan 1, 1976
-
Effect Of Three-Winding Transformer Models On The Analysis And Protection Of Mine Power SystemsBy Mathew P. Oommen, Jeffrey L. Kohler
Computer-aided loadflow and fault analyses of mine power systems are routinely conducted to ascertain system performance and also to provide information to assist in the protection and coordination of