Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Interpretation Of Full Scale Horizontal Pile Loading Tests In Sand Analysis Of P-Y Curves

    By Ali Bouafia

    Five full-scale horizontal loading tests of piles carried out by the LCPC in France are interpreted in order to analyse P-Y load-transfer curves. The experimental piles are either bored or jacked into

    Jan 1, 2002

  • DFI
    Assessment Of Safe Load On Piles Using Indian Standard Codeprivate ? Synopsis

    By Shenbaga R. Kaniraj

    The pile loading tests are generally conducted to assess the safe load on piles in compression. In the Indian practice, the safe load is determined using the pile loading test data and the two criteri

    Jan 1, 1996

  • DFI
    Towards a Performance-Based Design of Drilled Shafts

    By Kam Ng

    For bridges or buildings that may be subjected to large vertical and lateral loads, drilled shafts offer an economic foundation solution. While the current drilled shaft design practice is considered

    Jan 1, 2013

  • DFI
    Foundation Performance of Millennium Tower in San Francisco, California

    By John A. Egan, Nathaniel Wagner, Micaela Largent, Jonathan P. Stewart, Debra Murphy, Jeremy Butkovich

    The Millennium Tower is a 58-story reinforced concrete building that was constructed in San Francisco, California between 2005 and 2009. The Tower is founded on an embedded pile supported mat with pil

    Sep 8, 2021

  • DFI
    Deep Soil Mixing Use in Poland

    By Michal Topolnicki

    Deep Mixing Series: This article is the second keynote highlighted from DFI's virtual Deep Mixing Conference in 2021, for which Topolnicki served as a committeee co-chair Polish applications of deep s

    Apr 1, 2022

  • DFI
    I Don't Have X-ray Vision: Risk-Informed Site Investigation

    By Georgette Hlepas

    How often phrases like these have been made by project managers and project teams trying to explain why there has been cost growth, project delays and differing site conditions claims. But does it re

    May 1, 2022

  • DFI
    The Benefits of Early Contractor Involvement

    By Robert Small, Amshu Chappa, Ihab Allam

    The Biosolids Digester Facilities Project (BDFP) is located in southeast San Francisco. The jobsite is bounded by active Caltrain and Union Pacific Railroad tracks on the west side and the existing So

    Jan 1, 2023

  • DFI
    Depth Of Borings, Length Of Piles, Landslides, Erosion, And A Moose Hunt - A Case History Of A Comedy Of Mistakes

    By Bengt H. Fellenius

    An upgrading and straightening of a highway included building a bridge across a small river. A routine site investigation was initiated to determine the conditions for designing the foundation of the

    Jan 1, 1987

  • DFI
    Analysis Of Vibratory Driven Pile ? Introduction

    By Sherrill Gardner

    Vibratory drivers have been used since the 1930s to drive and extract piles. Vibratory pile drivers have the capability of significantly decreasing pile installation time, especially in granular type

    Jan 1, 1987

  • DFI
    Stabilizing A 100 Ft Rock Slope With Limited Access And Tight Construction Tolerances Using Observational Method And Real-time 3d Modeling

    By Travis A. Shoemaker, Mitchell S. Youmans, Nancy T. Chin, Michael S. Senior

    A geologic assessment and stability analysis of the right abutment of Boundary Hydroelectric Dam in Pend Oreille County, Washington was completed in May 2017. The stability analyses identified a poten

  • DFI
    Deep Excavation And Earth Retaining Structure ? Synopsis

    By S. Y. Zhou

    Excavation with earth retaining is one of the main technological means in deep foundations and underground engineerings. Several construction methods which have been used in China are introduced here

    Jan 1, 2010

  • DFI
    Tension Tests On Driven Pipe Piles In Sand - Synopsis

    By Alan J. Lutenegger

    A series of tension tests were performed on prototype scale steel pipe piles at two sites to evaluate the influence of scale and pile plugging on the unit skin friction developed in axial tension. The

    Jan 1, 2000

  • DFI
    Practice Of Arranging Drilling Piles In Subsiding Grounds

    By Vladimir M. Korolev

    The field studies conducted at the experimental-production sites allowed to develop the technology of arranging drilling piles in loess subsiding grounds over 25 m deep and over 250 mm in diameter, to

    Jan 1, 2002

  • DFI
    Parametric Analysis Of Piled Rafts Founded On A Tropical Clay Of Brazil

    By Renato P. Cunha

    The paper presents the results of a comparative and parametric analysis in which a numerical program developed exclusively for groups of deep foundations under general loading (vertical, horizontal an

    Jan 1, 2002

  • DFI
    Vibrodriving And The Compaction Of Granular Soils

    By RAP Bement

    Installation by vibrodrivers of sheet and bearing piles generates periodic vibrations in the surrounding ground, which have been widely measured and reported. One of the possible consequential effects

    Jan 1, 1996

  • DFI
    Cone Penetration Testing Can Save Money (and Trouble)

    By Rob van Dorp

    Most traditional foundation designs are based on soil investigations using Standard Penetration Testing (SPT), sometimes combined with static load testing on sacrificial trial piles. However, this des

    May 1, 2022

  • DFI
    Relevance Of Ryznar Index In Under Water Concrete - Synopsis

    By V. T. Ganpule

    The effect of Sulphate and Chloride is well understood by the engineers. Most of the codes stipulate permissible limits for sulphate and chloride content in groundwater. Relatively few reference are a

    Jan 1, 1996

  • DFI
    Piled Raft System - Approximate Design Methods. - Synopsis

    By S. L. Karunakaran

    There are cases where it is found that a raft foundation would have adequate factor of safety against ultimate bearing capacity failure but the settlements would be excessive. Piles may be introduced

    Jan 1, 1996

  • DFI
    2022 OPA Winner: Mosul Dam Rehabilitation Project

    By Raffaella Granta

    Mosul Dam is an earth fill dam located on the Tigris River, approximately 40 km (25 mi) northwest of Mosul, Iraq. The construction of the dam was completed in 1984. It is one of the largest multipurpo

    Oct 1, 2022

  • DFI
    Talking Dirty: How the Language We Use Affects the Foundation Industry

    By Ashley Shirer

    Have you heard a geotechnical engineer rail against using the word "dirt"? The typical maxim is: "It's not dirt, it's soil!" This axiom is so prevalent that it is joked about on the construction site.

    May 1, 2023