Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    The Use of Bentonite in Underground Construction

    By Hector Simchas

    "1. BENTONITE: THE CRUCIAL CONSTITUENT OF SLURRYSuspensions of bentonite and water are used in a variety of applications in underground engineering. For the construction of underground elements like s

    Jan 1, 2015

  • DFI
    Interactive Encased Stone-Column Foundation - Synopsis

    By P. M. Deshpande

    An interactive short column system is evolved as alternative to deep foundation system in deep layers of marine clay, the interaction of encased stone column and marine clay carry load without causing

    Jan 1, 1996

  • DFI
    Deep Excavation And Earth Retaining Structure ? Synopsis

    By S. Y. Zhou

    Excavation with earth retaining is one of the main technological means in deep foundations and underground engineerings. Several construction methods which have been used in China are introduced here

    Jan 1, 2010

  • DFI
    Interpreting Strain Measurements From Load Tests In Bored Piles

    By Jack Hayes

    Vibrating wire strain gages have proven to be a very reliable and effective tool for the measurement of strains associated with the loading of bored piles (drilled shafts). However, when these strains

    Jan 1, 2002

  • DFI
    Seven Mile Dam Retrofit - A Global Challenge

    By Arvindh Gupta

    BC Hydro proposed to improve the stability of the existing Seven Mile Dam with 54 corrosion protected, re-stressable anchors comprising 92/0.6? strands each, in phase 2 of the program. Being globally

    Jan 1, 2004

  • DFI
    Static Behavior Of Single Piles Subjected To Repeated And Reciprocating Loadings ? Synopsis

    By L. Z. Xie

    The results of the experimental study on the static behavior of single piles subjected to repeated and reciprocating axial loadings are recommended in this paper. Tests of four full-scale single piles

    Jan 1, 2010

  • DFI
    Effects Of Environment On Deep Foundation Elements - Synopsis

    By Subhash B. Bhide

    Deep foundations are affected by the presence of sulphates, chlorides, organic contents and water currents present in the soil. The sulphates in soil and ground water interfere first with setting of c

    Jan 1, 1996

  • DFI
    Drilled Piers Support Massive Gantry Crane

    By John R. Davie

    This paper describes the design and construction of two 5.6 MN capacity drilled piers installed to support the main loading elements of a large cantilevered gantry crane. The critical crane columns we

    Jan 1, 2006

  • DFI
    Optimization of Deep Foundation Design in a Sand, Gravel and Cobble Formation USING PRESSUREMETER TESTING IN SLOTTED SLEEVE CASING

    By Emad Farouz, Roger Failmezger

    "The proposed reconstruction of I-75 downtown consists of widening an approximately 2.46 Km section of IR-75 through the northern section of downtown Dayton, OH, USA. Bridge B-13 is a 9-span continuos

    Jan 1, 2007

  • DFI
    Assessment Of Safe Load On Piles Using Indian Standard Codeprivate ? Synopsis

    By Shenbaga R. Kaniraj

    The pile loading tests are generally conducted to assess the safe load on piles in compression. In the Indian practice, the safe load is determined using the pile loading test data and the two criteri

    Jan 1, 1996

  • DFI
    Capacity Prediction Vs. Performance Of Driven Pre-Cast Pre-Stressed Concrete Piles In Chesapeake, Virginia

    By Emad Farouz

    This paper compares the predicted axial capacity of driven Pre-cast Pre-stressed Concrete (PPC) piles for the Lake Gaston Water Treatment Plant (LGWTP) using several design methodologies versus the ax

    Jan 1, 2007

  • DFI
    Towards a Performance-Based Design of Drilled Shafts

    By Kam Ng

    For bridges or buildings that may be subjected to large vertical and lateral loads, drilled shafts offer an economic foundation solution. While the current drilled shaft design practice is considered

    Jan 1, 2013

  • DFI
    Foundation Performance of Millennium Tower in San Francisco, California

    By John A. Egan, Nathaniel Wagner, Micaela Largent, Jonathan P. Stewart, Debra Murphy, Jeremy Butkovich

    The Millennium Tower is a 58-story reinforced concrete building that was constructed in San Francisco, California between 2005 and 2009. The Tower is founded on an embedded pile supported mat with pil

    Sep 8, 2021

  • DFI
    Deep Soil Mixing Use in Poland

    By Michal Topolnicki

    Deep Mixing Series: This article is the second keynote highlighted from DFI's virtual Deep Mixing Conference in 2021, for which Topolnicki served as a committeee co-chair Polish applications of deep s

    Apr 1, 2022

  • DFI
    I Don't Have X-ray Vision: Risk-Informed Site Investigation

    By Georgette Hlepas

    How often phrases like these have been made by project managers and project teams trying to explain why there has been cost growth, project delays and differing site conditions claims. But does it re

    May 1, 2022

  • DFI
    Depth Of Borings, Length Of Piles, Landslides, Erosion, And A Moose Hunt - A Case History Of A Comedy Of Mistakes

    By Bengt H. Fellenius

    An upgrading and straightening of a highway included building a bridge across a small river. A routine site investigation was initiated to determine the conditions for designing the foundation of the

    Jan 1, 1987

  • DFI
    Installing And Testing Multi-bar High Capacity Rock Tiedowns

    By Andrew Pontecorvo, Steven Lowe, David Sposito

    Buildings with large height-to-width ratios require foundations with significant uplift resistance. This paper presents a case study of the permanent rock tiedowns installed for One Manhattan West, a

  • DFI
    Stabilizing A 100 Ft Rock Slope With Limited Access And Tight Construction Tolerances Using Observational Method And Real-time 3d Modeling

    By Travis A. Shoemaker, Mitchell S. Youmans, Nancy T. Chin, Michael S. Senior

    A geologic assessment and stability analysis of the right abutment of Boundary Hydroelectric Dam in Pend Oreille County, Washington was completed in May 2017. The stability analyses identified a poten

  • DFI
    Tension Tests On Driven Pipe Piles In Sand - Synopsis

    By Alan J. Lutenegger

    A series of tension tests were performed on prototype scale steel pipe piles at two sites to evaluate the influence of scale and pile plugging on the unit skin friction developed in axial tension. The

    Jan 1, 2000

  • DFI
    Parametric Analysis Of Piled Rafts Founded On A Tropical Clay Of Brazil

    By Renato P. Cunha

    The paper presents the results of a comparative and parametric analysis in which a numerical program developed exclusively for groups of deep foundations under general loading (vertical, horizontal an

    Jan 1, 2002