Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
-
Instabilidade Plástica Em Cilindro De Paredes Finas Sujeito À Pressão Interna – Estudo De CasoBy Anselmo Monteiro Ilkiu
No presente trabalho será apresentado um modelo matemático para a análise da instabilidade plástica de um cilindro de parede fina sujeita a pressão interna, considerando o material com anisotropia nor
Aug 16, 2017
-
Instability analysis in three-way and four-way coal mine intersectionsBy B Abbasi
It is well known that most roof falls in coal mines typically occur at and around intersections. Room-and-pillar and longwall coal mining systems typically develop 3-way and 4-way intersections. This
Nov 30, 2018
-
Instability Mechanism of a Multi-Layer Gangue Roof and Determination of Support Resistance Under Inclination and Gravity "Mining, Metallurgy & Exploration (2020)"By Panshi Xie, Yingyi Zhang, JIANJIE DUAN, Shenghu Luo
A multi-layer gangue roof of a steeply dipping coal seam with a large mining height face area was analyzed using physical simulation, numerical simulation, theoretical analysis, and field measurement
Jun 30, 2020
-
Instability of topsoil benches of a pit caused by dumping of waste rock outside an opencast coal mineBy A. Golder, S. P. Dandapat, I. Roy
One of the consequences of large-scale opencast mining for coal is the disposal of an enormous volume of overburden material that needs to be removed. With the enlargement of opencast mines and associ
Nov 27, 2024
-
Instalación de un sistema de remolienda con ciclones, sin usar molinas de barras, en la planta Sacracancha del Banco Minero del PerúBy Personal técnico de la concentradora
El objetivo del trabajo es señalar los beneficios obtenidos en la planta Sacracancha a través de la instalación de un sistema económico de remolienda de baja inversión, readaptando sus molinos de bola
Aug 20, 1963
-
Installation And Operational Result Of Lindarctm Real Time Laser Off-gas Analysis System At Acciaierie Bertoli Safau - Abs (Italy) Electric Arc FurnaceBy Daniele Tolazzi
In today’s highly competitive market situation, it is of outmost importance for EAF steel makers to optimise their processes in order to reduce operating costs and to improve safety and reliability of
Aug 16, 2017
-
Installation And Performance Characteristics Of High Capacity Helical Piles In Cohesionless SoilsBy Mohammed Sakr
The use of helical piles as a deep foundation option has considerably increased in the recent years to support a variety of loads, from small loads for several applications such as residential housing
Jan 1, 2011
-
Installation And Performance Characteristics Of High Capacity Helical Piles In Cohesive SoilsBy Mohammed Sakr
This paper presents the results of a full-scale axial compression and tension (uplift) testing program executed on large-capacity helical piles installed in very stiff to very hard clay till soils (i.
Jan 1, 2012
-
Installation And Performance Of Interlocking Drilled Shaft And Tieback Shoring System - SummaryBy Alec C. Bloem
A 55' deep excavation encompassing almost a city block in London, Ontario required a lateral earth retention system to provide both temporary excavation support and a permanent groundwater cut-of
Jan 1, 1991
-
Installation And Testing Of 260 Hollow Core Bar MicropilesBy Jesús E. Gómez
A total of 260 micropiles were installed as part of a retrofit effort for two existing bridges. The micropiles consisted of hollow core bars installed under limited headroom conditions. Of the total n
Jan 1, 2007
-
Installation And Testing Of Instrumented Tieback Anchors - IntroductionBy Joan Stoupa
The expansion of the West Point wastewater treatment plant located in Seattle, Washington, will require a permanent tieback retaining wall to enlarge the plant site for the new treatment plant facili
Jan 1, 1990
-
Installation Of 0.84 M (33 In) Cyclones On The Primary Grinding Circuit At Cyprus Sierrita CorporationBy L. N. Hill
The classifiers on the primary grinding circuit at Cyprus Sierrita have been upgraded from 0.66 m (26 in) diameter hydrocyclones to 0.84 m (33 in) diameter hydrocyclones. This has resulted in a 4.3 %
Jan 1, 1994
-
Installation Of A Digital, Wireless, Strong-Motion Network For Monitoring Seismic Activity In A Western Colorado Coal Mining RegionBy Peter Swanson, Collin Stewart, Wendell Koontz
A seismic monitoring network has recently been installed in the North Fork Valley coal mining region of western Colorado as part of a NIOSH mine safety technology transfer project with two longwall co
-
Installation Of A New 80 T Mrp-l Converter At Aperam TimoteoBy Günther Staudinge
Aperam is a global player in producing of stainless, electrical and special steel qualities. The steelmaking plant in Timoteo Brasil is equipped with one AODconverter for stainless steel and one MRPL-
Aug 17, 2017
-
Installation Of A New Surface Fan At The Homestake Gold Mine ? IntroductionBy Greg Struble
The Homestake Gold Mine is one of the deepest and most extensively developed hardrock mines in North America. The mine is divided into five divisions which produce a total of 1.7 million metric tons o
Jan 1, 1987
-
Installation Of A State-Of-The-Art Ventilation Shaft At A New Mexico Coal MineBy A. Zeni, S. L. Bessinger, T. A. Palm
San Juan Coal Company (SJCC) operates an underground coal mine near Farmington, New Mexico. Continuous miners and a longwall produce 7-8 million tons per year. The coal seam at SJCC has tested to
Jan 1, 2006
-
Installation Of A Supervisory Control System At A Gold Pressure Oxidation Plant (edba5c85-6442-4bfd-bdfb-2b55fb328e40)By M. Spangler
FirstMiss Gold installed a supervisory control system based on Pavilion Technology's Process Insights neural network software and Oil System's PI data historian. The primary goal of the syst
Jan 1, 1995
-
Installation of a Ventilation Shaft at San Juan CoalBy T. Arthur Palm, Stephen L. Bessinger
San Juan Coal Co. (SJCC) operates an underground coal mine near Farmington, NM. Continuous miners and a longwall produce 6.3 to 7.2 Mt/a (7 million to 8 million stpy). SJCC is owned and operated by
Jan 1, 2007
-
Installation Of Augered Cast-In-Place PilesBy Michael Moran
Typical ACIP Pile Rig [ ] Hollow Stem Auger ? Continuous flight auger ? 3 inch inside diameter pipe ? Auger diameters: 12, 14, 16, 18, 20, 22, 24, 30, and 36 inches ? Auger section lengths:
Jan 1, 2005
-
Installation Of Augered Cast-In-Place Piles (3e8ab035-87ca-4b14-9759-c57d4f787aa0)By Tracy Brettmann
Equipment ? Hollow Stem Auger ? Drill Bits ? Leads/Torque Arm ? Hydraulic Gearbox ? Hydraulic Power Unit ? Grout Pump ? Crawler Crane
Jan 1, 2004