Simplified Pre-and Post-Processing Technique for Performing Finite-element Analyses of Deep Underground Mines (4c70a887-9438-4254-8d3e-3283730c59e0)By Marc T. Filigenzi
Two of the major ground control safety issues confronting underground mine operations today are shaft pillar stability and the failure of rock around active mine openings. Failure of a mine shaft can
Jan 1, 1997
-
Numerical Modeling for Increased Understanding of the Behavior and Performance of Coal Mine StoppingsBy Lisa Burke
In underground coal mines, concrete block stoppings are widely used to control mine ventilation. Although stoppings are not intended as roof support, they are subjected to roof to floor convergence, a
Jan 1, 2004
-
Determination And IT-Supported Evaluation Of Rock Mechanical Parameters And Their Utilization During Application Of Roof Bolting TechniquesBy Nikolaos Polysos
For the planning and driving of gateroads supported by roof bolts a practical concept has been developed in order to determine the geological and rock mechanical parameters derived from exploration dr
Jan 1, 2001
-
Further Improvements In The Roof Beam Tilt Method Of Gateroad Support DesignBy Peter Cain
Twenty years of research into the design of permanent gateroad support (packs) in coal mines have resulted in two methods of pack design based on engineering principles. The first, the detached block
Jan 1, 1993
-
Operational Experience With FLEXIBOLT Systems In Australian Coal MinesSince the initial development and trials of FLEXIBOLT flexible roof bolts, further comparative testing and product development has been completed as part of the changeover to this roof support system
Jan 1, 1994
-
Improved Design Of Coal Pillars For U.S. Mining ConditionsBy Z. T. Bieniawski
This paper presents the results of a survey of room and pillar dimensions and design practice in U.S. coal mines aimed at improving the design procedures in room and pillar mining. A review is given o
Jan 1, 1981
-
Experimental Study of Acoustic Emission Characteristics for Burst-prone Coal/Rock Fracture ProcessBy Liu Changyou
This paper analyzes experimentally the stress-strain relationship and the characteristics and variation trends of acoustic emission signals of the medium- and high-burst-prone coal/rock fracture proce
Jan 1, 2003
-
Application Of Tailing Sand And Water As Backfill Material In Metal Mines (1992)By Sun Henghu
This paper analyses problems associated with cement based technique in metal mines, and provides a new mining technique of packing the tailing sand and water into solidified material. In the new techn
Jan 1, 1992
-
Load And Deflection Response Of Ventilation Stoppings To Longwall Abutment Loading - A Case Study (49571726-6a2d-49b8-8ef0-957c4421195c)By David C. Oyler
Few studies have specifically measured and documented the large-scale loading behavior and durability of ventilation stoppings to mining induced movements, particularly from longwalls. Ventilation sto
Jan 1, 2001
-
Analysis Of Cable Bolt Performance Using Numerical ModelingBy M. Bouteldja
A finite element modelling approach is developed for the evaluation of the mechanical performance of cable bolts supports in underground mine structures. The modelling approach permits the simulation
Jan 1, 1999
-
Field Testing of a Real Time Roof Mapping Drilling Display System in a Limestone MineBy Craig Collins
The objective was to develop a Real Time Drilling Display System for Rotary Roof Bolting using Analyzing Software to display mapped holes as they are being drilled in real time. The Analyzing Softw
Jan 1, 2004
-
Application in Design for Close Proximity Multi-Seem MiningVirtually all mineable Appalachian coal seams exist in a multi-seam environment. This makes it inevitable that most seams will eventually experience interaction induced ground control and mining probl
Jan 1, 1987
-
Ground Control Worker Safety During Extended Cut MiningBy Roy H. Grau
The trend in underground room-and-pillar cod mining is to employ remote-control continuous mining machines to take extended cuts of 40 A or more. Roof fall safety hazards to the mine worker associated
Jan 1, 1997
-
Quality Management For Grouted RockboltsBy Dieter Wittenberg
The successful extension of the applications in which rockbolts can be used in the German coalmining industry is, because of the very great raining depth combined with a high degree of stress in the n
Jan 1, 2000
-
Subsidence Monitoring Results, Thick Seam Longwall Mining In WyomingBy Collin L. Stewart
A summary of the results of a limited subsidence monitoring program at Cyprus Amax Coal Company's Shoshone Mine No. 1 in the Hanna Basin of south central Wyoming is presented. The monitoring prog
Jan 1, 1995
-
Failure Mechanics of Multiple Seam Mining Interactions (f9d85dbe-da66-4f30-9b39-e277c41aff64)By R. Karl Zipf
Multiple seam mining interactions caused by full extraction mining, whether due to undermining or overmining, frequently involve tensile failure of the affected mine roof. The adverse ground control c
Jan 1, 2005
-
Inorganic Cement Grouted Bolt SystemBy M. O. Serbousek
In 1975 the Bureau of Mines Spokane Research Center began a series of laboratory and field tests to investigate the feasibility of developing a substitute for the organic chemicals used in resin roof-
Jan 1, 1981
-
Updating the NlOSH Support Technology Optimization Program (STOP) With New Support Technologies and Additional Design FeaturesBy Thomas M. Barczak
The initial Support Technology Optimization Program (STOP), Version 1.0, was released at the 19th Gmund Control Conference. This original program has since been updated to Version 2.3 which was releas
Jan 1, 2001
-
Practical Aspects Of Longwall Pillar DesignBy Christopher Mark
The past decade has provided a wealth of practical experience with longwall pillar design. Design formulas developed specifically for longwalls have proven their value in numerous applications. Analyt
Jan 1, 1990
-
A Case Study of Bolt Performance in a Two-entry GateroadBy Stephen P. Signer
This paper presents the results of a case study conducted in a two-entry gateroad in a coal mine where excessive roof deformation and bolt loading resulted in failure of many roof supports. The instru
Jan 1, 1998