    Dust Capture Performance Of A Water Exhaust Conditioner For Roof Bolting Machines

    By Timothy W. Beck

    Roof bolter occupations in underground coal mines continue to experience overexposure to respirable dust. One potential source of dust in roof bolting operations is the exhaust from the roof bolter du

    Jan 1, 2010

  • CIM
    Dust Collection Methods for Primary and Secondary Crushing (NOVEMBER 21, 1975 )

    By D. Ingram

    "PRIMARY DUST COLLECTOR A. 42,000 CFM James Howden Fan Z-6 Size 3650 Fan Dia 40"" HP 75It was found that the fan was not large enough to remove the air that was displaced by the trucks dumping. So it

    Jan 1, 1976

  • CIM
    Dust Control at Granisle Copper

    By L. W. Hamel

    "DUST CONTROL - GRANISLE COPPER LIMITEDINTRODUCTIONGranisle. Copper Limited is located in the north-central region of the Province of British Columbia, approximately 200 road miles north-west of Princ

    Jan 1, 1976

  • CIM
    Dust Control at Steep Rock Iron Mines Pelletizing Plant

    By P. S. Capper

    "Generally speaking, the most intensive efforts at dust control in the mining industry have, in the past, been concerned with underground operations and where uranium ore or high silica material is pr

    Jan 1, 1976

  • CIM
    Dust Control at the Cassiar Asbestos Primary Crushing Plant

    By F. J. MacPherson, A. C. Caron

    "Cassiar Asbestos Corporation Limited is at present B,C.'s only asbestos mining company, and has been actively engaged in the management and operation of the Cassiar Mine since the early 1950's. The C

    Jan 1, 1976

  • SME
    Dust Control Considerations For Deep-Cut Faces When Using Exhaust Ventilation and a Flooded-Bed Scrubber - Preprint 97-48

    By R. A. Jankowski

    The U.S. Bureau of Mines (USBM) conducted a series of laboratory tests to investigate the effectiveness of using a flooded-bed scrubber with exhaust ventilation in deep-cut faces of up to 12.2 m in le

    Feb 24, 1997

  • SME
    Dust Control for Coal Handling : Design Considerations and Solutions

    By Henning E. Soderberg, Robert Brien, O&apos

    Coal may be the answer to US energy problems, but it also has its drawbacks. If it is crushed, screened, dumped, or moved, the environmental engineer is faced with a dust problem. To control coal d

    Jan 10, 1981

  • AIME
    Dust Control In Longwall Shearer Faces Through Air Movement By Water Sprays

    By Fred N. Kissell, Natesa I. Jayaraman

    Introduction This paper describes a recent Bureau of Mines research project that resulted in a simple procedure for reducing the dust exposure of longwall shearer operators. This project involved the

    Jan 1, 1981

  • SME
    Dust control in room-and pillar coal mining using continuous miners: Additional field evaluations

    By Y. P. Chugh

    Additional field evaluations of a modified continuous miner using a new spray system and modified scrubbers have been conducted by the authors. In this demonstration, a comprehensive package for dust

    Jan 1, 2009

  • NIOSH
    Dust Control On Longwalls – Assessment Of The State-Of-The-Art

    By J. P. Rider

    Operating practices and resulting production from longwall faces are continually improving. Consequently, longwall operators are continually seeking to improve the dust control capabilities on longwal

  • NIOSH
    Dust Control Practices For Underground Coal Mining

    By Edward D. Thimons, Jay F. Colinet

    Underground coal mining operations in the United States continue to increase productivity as mining equipment and practices are improved. Unfortunately, increased production also results in the poten

  • CIM
    Dust Control, Brenda Mines Limited, Peachland B.C.

    By J. W. Austin

    "Introduction The Brenda dust collection system was originally designed to handle air at the 5000 ft. elevation with less than 1 grain of dust per cubic feet of air handled. The temperature variation

    Jan 1, 1976

  • NIOSH
    Dust Exhaust System For Auger Miners - Objective:

    Reduce respirable dust exposure of workmen operating auger-type continuous mining machines. Approach: An auger miner was fitted with an exhaust system which draws dust laden air through a [scru

    Jan 1, 1976

  • CIM
    Dust Handling Systems for Flash Furnaces

    By Thomas. Lisa, Mark Coleman

    Schenck Process is an established customer-driven solutions provider, utilising its knowledge, expertise and technologies to transform production processes. Operating across several industries Schenck

    Jan 1, 2019

  • NIOSH
    Dust Protection For Bag Stackers

    Bag stackers who use semi-automated palletizing machines and air slides may be exposed to high concentrations of dust. To reduce dust exposure, use an exhaust ventilation system in conjunction with an

    Jan 7, 2001

  • NIOSH
    Dust Underfoot - Enclosed Cab-Floor Heaters Can Significantly Increase Operator’s Respirable Dust Exposure

    By Andrew Cecala, John Organiscak, William Heitbrink

    Many types of heavy equipment used in the mining and construction industries use enclosed cabs to protect equipment operators from dust and noise exposure. Normally, when the equip- [ ] ment is new,

  • ISEE
    Dutch Harbor, Alaska Unisea Quarry – Using Near Field Vibration Measurements to Improve Blasting Results Close to Structures

    By Mike Cammack, Logan Huppert, Gustavo Azpilcueta

    During the summer of 2015, Unisea Inc. sought proposals for the G1 Dock Replacement Project in Dutch Harbor, Alaska. It would be a one year project and construction was scheduled to begin in the sprin

    Jan 1, 2018

  • CIM
    Dye Penetration Techniques Used to Determine Heap Leach Potential of a Telluride bearing Cripple Creek Breccia Ore

    By Marc D. Melker, Geoffrey R. Lane, Michael Jahraus

    "The Cresson gold deposit is located in the Cripple Creek district of Colorado. The deposit is composed of volcanic intrusive rocks and volcanogenic sediments where gold mineralization is associated w

    Jan 1, 2006

  • DFI
    DYNA Force-An Elasto-Magnetic Sensor For Force Measuring Of Post Tensioning Ground Anchors

    By Lucian Bogdan

    On many occasions during construction and service life of the structure, it is crucial to know the load in post tensioning tendons and anchors. Although there are many methods to measure the tendon fo

    Jan 1, 2009

  • DFI
    Dynamic Analysis Correlation Of Standard Penetration Resistances With The Adhesion Of Very Stiff To Hard Clays On Driven Piles

    By Chris D. Thompson

    In Southern Ontario, Canada, piles are frequently driven through competent clayey soils to obtain end bearing on extremely dense till or bedrock. One reason for this is the difficulty at assessing the

    Jan 1, 2002