Search Documents
Search Again
Search Again
Refine Search
Refine Search
-
Analysis Of Roof Bolt Systems (80829435-dd55-4b61-96dd-df38d097e9ff)By Christopher Mark
Despite more than half a century of experience with roof bolting, no design method has received wide acceptance. To begin to improve this situation, National Institute for Occupational Safety and Heal
Jan 1, 2001
-
Stone Mine Design in Highly Fractured Rock (af82e9d2-530a-42f2-9d22-f8c466af0da2)By Vincent Scovazzo
Cost-effective underground mine configurations have been designed in highly fractured rock masses where the stone possesses a high material strength. A limestone mine in the eastern United States is u
Jan 1, 2002
-
Tension-Torque Relationship For Mechanical Anchored Roof BoltsBy H. N. Maleki
Tension-torque relationships were investigated *n a coal mine for bath standard 5/8 in. (16 mm) bolts and a vibrating wire instrumented bolt, using conventional and controlled installation techniques.
Jan 1, 1984
-
Modelling Of Pillar Stability In Room And Pillar MinesBy Douglas Morrison
By applying modern 3D numerical modelling techniques to the analysis of a pillar cascade failure in a room and pillar mine, it has been possible to simulate the collapse and develop an understanding o
Jan 1, 2003
-
New Tools For Roof Support Evaluation And Design (64c31d00-3878-45a5-a962-d673afed7598)By Steve Signer
Researchers at the National Institute for Occupational Safety and Health (NIOSH) have developed several new tools for evaluating roof support performance. A miniature data acquisition system (MIDAS) w
Jan 1, 2003
-
Coal Mine Seismicity And Bumps: Historical Case Studies And Current Field ActivityBy John L. Ellenberger
The National Institute for Occupational Safety and Health (NIOSH) has continued the research role of the former U.S. Bureau of Mines to develop techniques that will reduce the hazards in the mining wo
Jan 1, 2000
-
Design, Monitoring And Evaluation Of A Pre-Driven Longwall Recovery RoomBy Tom Wynne
In order to shorten the time required and improve safety for a longwall face move, a 36-ft wide longwall recovery room was predriven. The room was supported with specialty bolts, trusses and concre
Jan 1, 1993
-
Influence Of Support Capacity And Geometry On Tailgate SupportBy E. Hosca
Alternative tailgate loading conditions due to conventional and conventional/yield pillar combinations were evaluated to define roof loading. In order to isolate different loading situations, the tail
Jan 1, 1994
-
Investigation into the Extent and Mechanisms of Gloving and Un-mixed Resin in Fully Encapsulated Roof BoltsEffective strata control, utilising fully encapsulated roof bolts, is dependent on the installed quality of the reinforcement elements. One mechanism by which fully encapsulated roof bolts may become
Jan 1, 2003
-
Optimization Of Bench Blast Design With The Aid Of Computer (febe1846-7d11-4969-9dc5-f8d6a8a628b1)By Wei Wu
A new bench blast design method and its realization with the assistance of the computer is introduced. The basic design principle is to define a rhomb cell, called fully-fractured zone, through a seri
Jan 1, 1992
-
INSTáL CableOx: A New Tensionable & Corrosion Resistant Cable BoltBy John C. Stankus
The success of cable bolts for mine ground control have been well documented in papers presented at this conference too numerous to reference. Cable bolts have proven effective over the years mainly u
Jan 1, 2000
-
Application in Design for Close Proximity Multi-Seem MiningVirtually all mineable Appalachian coal seams exist in a multi-seam environment. This makes it inevitable that most seams will eventually experience interaction induced ground control and mining probl
Jan 1, 1987
-
Roof Behavior In South African Coal Room And Pillar PanelsBy Bruce W. Jack
An extensive underground roof-monitoring program was conducted in order to determine the roof strata behavior under various conditions. In total 29 sites at 5 different collieries were monitored using
Jan 1, 2000
-
A Lineament Analysis Case Study of the Fola Coal Co., LLC. No. 2 Surface Mine, West VirginiaBy Paul L. Tyrna
The Fola Coal Co., LLC No 2 surface mine, located in Nicholas and Clay Counties, WV, exploits up to nine coal seams by contour, highwall, and mountain top removal mining methods. After encountering fa
Jan 1, 2001
-
Geotechnical Aspects of Subsidence over Room and Pillar Mines in IllinoisBy Gennaro G. Marino
Site conditions at several shallow room and pillar mines in Illinois are described and compared with the charac¬teristics of the subsidence profiles at the ground surface. The shape and magnitude of t
Jan 1, 1984
-
Laboratory Strength Testing of Coal from Selected Illinois SeamsBy E. Bane Kroeger
For many years, researchers around the world have been investigating coal pillar stability. Many have focused on trying to optimize the size of the pillars by examining stable and failed pillars in un
Jan 1, 2004
-
Progress In The Development Of A Roof Bolt Design Methodology Based On Resisting ShearBy Ross Seedsman
There are many models for how roof bolts behave, one of which is prevention of shear along bedding. The basis of this model is that a roof beam will not delaminate if bedding parallel shear can be pre
Jan 1, 2000
-
Field Testing of the Fully Grouted Thrust Tensioned BoltsBy Kot Unrug
Fully grouted tensioned bolts provide a desirable compressive of laminated roof and bondage along the entire bolt length, at the same time the entire surface of the hole is protected against penetrati
Jan 1, 2002
-
Pillarless Longwall Mining For Multiple SeamsBy Victor V. Nazimko
Longwall mining technology without interpanel pillars is feasible from a geomechanical point of view. A set of pillarless longwall layouts are proposed including tailentry pillar recovery, headentry p
Jan 1, 1994
-
Problems in "Void" Detection in Coal Mine Water HazardsBy Francis Kendorski
One of the most dangerous events in underground coal mining is unexpectedly encountering water inrushes from undetected abandoned mines in the same seam. The surest and most confident method is probe
Jan 1, 2004