Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Measurements of CDSM Strengths and Seepage Data Following Seismic Upgrades of San Pablo Dam

    By Atta B. Yiadom, A. David Miller, Robert C. Kirby, Sean M. Todaro

    "San Pablo Dam is a 170-foot (52-meter)-high earthfill embankment, located approximately 10 miles (16 kilometers) north of downtown Oakland, California, that impounds a 38,600 acre-feet (47.6 million

    Jan 1, 2015

  • DFI
    Research on the Stability Analysis of TDM Column Composite Foundation Supported Embankment

    By Song-yu Liu, Chao Yan, Yong-feng Deng

    "In order to investigate the stability of embankment on soft subgrade improved by T-shaped deep mixed column composite foundation, the internal forces and failure modes of columns were analyzed on the

    Jan 1, 2015

  • DFI
    Case Study: Load Transfer Analysis on an Instrumented Augercast Pile Using EDC Strain Gauges and Geokon Rebar Strainmeters

    By Sastry Putcha, Santosh Mummaneni, Swamy Avasarala, Vamshi Vemula

    "This paper presents the results from a case study on the comparison of two strain acquisition instrumentation technologies, Geokon rebar strainmeters and Embedded Data Collectors (EDC) for the DC Wat

    Jan 1, 1900

  • DFI
    Hybrid Energy System Installed on Deep Mixing Barge

    By Kento Miyamoto, Kazuki Imamura, Takayuki Tanaka

    "Global economic development has drastically increased energy consumption in various fields, and CO2 emissions, which are a prime cause of global warming, have continued to increase. Therefore, measur

    Jan 1, 2015

  • DFI
    A Review Low Strain Integrity Testing Practices In India And Complexities Involved In Evaluation Of Test Results

    By RavikiranVaidya, Vishal Dhamecha

    Low Strain Pile Integrity Testing has been used in India since 1990’s and several have tried to demonstrate the utility and benefits of this method. However, use of this technology was limited till 19

    Sep 1, 2022

  • DFI
    Lateral Behavior Of Post Grouted Drilled Shafts

    By Emad Farouz, Ehab S. Shatnawi, Charles Winter

    The increasing demand for small deformations and high-capacity drilled shafts without enlarging drilled-shaft diameters has motivated the development and increased use of a base grouting (BG) techniqu

  • DFI
    Instrumented Pile Load Tests on ACIP Piles for a Real Estate Project in Kolkata-A-Case Study

    By Krishnendu Mandal

    "For a multi-story building project in Kolkata, a pile load testing program was conducted to minimize pile performance uncertainty resulting from variable subsurface conditions and to verify the pile

    Jan 1, 2015

  • DFI
    St. Croix Bridge, Minnesota: The Influence of Construction on the Axial Resistance of Drilled Shaft Foundations in Weak Sandstone

    By William G. Ryan, David S. Graham, Dan A. Brown, Rich A. Lamb, Paul J. Axtell

    "The St. Croix River Crossing project on the Minnesota-Wisconsin border has been in the process of planning and public debate for two decades, with several changes in alignment. During the course of t

    Jan 1, 2015

  • DFI
    Driven Pipe Pile Solutions for the Temporary Foundations at the New San Francisco-Oakland Bay Bridge

    By Manuel M. Reyes, Thuraisamy Thavaraj, Alex Sy

    "The new east span of the San Francisco-Oakland Bridge features a single tower self-anchored suspension (SAS) bridge. During construction of the SAS bridge, a temporary bridge was used to support the

    Jan 1, 2015

  • DFI
    Seismic Remediation of Perris Dam

    By Michael W. Driller, Wen Yan (Grace) Chen, Steven J. Friesen

    "Remediation for Perris Dam has been proposed in response to deficiencies identified in a seismic stability study prepared by the California Department of Water Resources (DWR) in 2005. Lenses of pote

    Jan 1, 2015

  • DFI
    The Effects of Cylindrical Pile Insertion on the Vertical Stiffness and Strength of the Surrounding Soil

    By Emre Biringen

    "Results from a small-scale laboratory experimental program show the changes in the vertical stiffness and strength of a soft clayey soil adjacent to the shaft of an inserted pile (i.e. expansion of a

    Jan 1, 2005

  • DFI
    Challenges And Recommendations For Quality Assurance Of Deep Foundations

    By Frank Rausche

    Although Quality Control (QC) during construction is preferable for deep foundations, there are many instances when it is necessary to resort to Quality Assurance (QA) methods if, for various reasons,

    Jan 1, 2008

  • DFI
    Centrifuge Modelling Of Displacement Piles and Installation Effects

    By J. Gniel, L. King, C. Gaudin, C. O’Loughlin

    "This paper presents some recent advancements in centrifuge modelling, which enable the installation of displacement piles to be performed in-flight while measuring ground responses. Details and resul

    Jan 1, 1900

  • DFI
    DFI 2008 Outstanding Project Award Winner Intricate Excavation for the New South Ferry Subway Station

    By Alice Arana, David M. Cacoilo, Joel L. Volterra

    "To make space for the new South Ferry Station in lower Manhattan, engineers and contractors carved out a new tunnel beneath three operating subway tunnels and tangentially to yet another tunnel. Crea

    Jan 1, 2008

  • DFI
    Quality Assessment Of Drilled Shaft Foundations At The Jane Byrne Interchange

    By Travis Coleman, Elvis Ishimwe

    Currently, more than 400 drilled shafts have been constructed by various contractors at the I-90/94 and I-290 Jane Byrne (Circle) Interchange, located near downtown Chicago, Illinois. Cross-Hole Sonic

  • DFI
    Design And Field Comparison Of Ground Improvement And Bored Piles For Large Diameter Steel Water Tanks

    By Vijaya Bhushan Rao, Ali Semercioglu, Jason Redgers

    Large diameter steel water tanks with high storage capacities impart heavy loads deep into the ground, generally requiring deep foundations to adequately support them. The use of ground improvement as

    Oct 1, 2022

  • DFI
    Comparison of Drilled Shaft Structural Response from Strain Gage and Shape Accel Array (SAA) Data

    By J. Erik Loehr, Minh Uong, Andrew Z. Boeckmann, Sarah G. Myers

    "The University of Missouri performed a lateral load test program involving 32 drilled shaft load tests for the Missouri Department of Transportation (MoDOT). Tests were performed at two MoDOT geotech

    Jan 1, 2017

  • DFI
    Risk Assessment and Quality Control on Grouted Waterretaining Layers by Observational Engineering

    By Bartho J. Admiraal

    "As part of the Schiphol-Amsterdam-Almere project, the largest aqueduct in Europe is being built in order for the A1 motorway to cross the Vecht River. The A1 consists of 12 lanes and the total width

    Jan 1, 2016

  • DFI
    30 Hudson Street Foundation Design and Construction in Variable Rock

    By Joel Moskowitz, George J. Tamaro

    "A new office complex is being constructed within 25m of the Hudson River in New Jersey. The project, about 140m by 100m, will include 4 basements under the entire footprint. The perimeter was to be s

    Jan 1, 2004

  • DFI
    Pile Design and Construction Challenges in Partially Thawed Alaskan Soils (f9ca4371-20bf-4196-a495-4aa1bd15a8c0)

    By John D. Thornley

    Alaskan villages typically store a one-year supply of fuel to reduce significant delivery costs. Alaska Village Electric Cooperative (AVEC), an electric utility cooperative providing power to 51 Alask

    Jan 1, 2017