Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
-
Behaviour Of Model Pile Group Under Axial Monotonic LoadingBy A. Le Kouby
We present in this paper the results of a parametric study carried out in a calibration chamber on instrumented model piles. The aim is to point out group effect on piles within a group through their
Jan 1, 2006
-
Analysis And Design Of A Piled Foundation For A Tall Tower ? SynopsisBy I. K. Ozaydin
Analysis of piles groups loaded with large bending moments and both vertical and batter piles can be best performed by matrix analysis. In this paper, a case history about a tall marine control tower
Jan 1, 2010
-
Stone Columns At Trenton Water Treatment Facility - Suitable Alternative To Remove And Replace For Mat FoundationBy Darrell Wilder
The Trenton Water Treatment Facility in Trenton, New Jersey, is expanding to upgrade existing facilities and to meet the increasing demands of the public. The facility sits uncomfortably between the
Jan 1, 2008
-
Segmented Prestressed Concrete Piles For Coastal Environments ? SynopsisBy S. Ahmed
Critical factors of selection, fabrication, installation, and splicing of prestressed concrete piles are discussed based on experiences with coastal subsurface conditions of the United States of Ameri
Jan 1, 2010
-
Innovative Methods Of Dealing With Contaminated Soils In Drilled Shafts - SynopsisBy William F. Loftus
When high capacity diameter pipe piles are driven open-ended into the underlying bedrock, the material gathered inside the pipe often must be excavated to allow concrete to be placed within, in a clea
Jan 1, 1996
-
Pier Design And Construction In Water Bearing Soils ? SynopsisBy C. N. Baker
The design and construction of drilled piers through water bearing and caving soil conditions are discussed. The need for close cooperation between the design engineer and contractor in both the desig
Jan 1, 2010
-
Design Criteria Of Dynamic Consolidation ? SynopsisBy Z. Q. Wang
The author is trying to clarify the existing problems in designing and laying out dynamic consolidation for soft ground improvement. Field testings and observations including vibrational parameters, p
Jan 1, 2010
-
Design Method For Bridge Abutment Foundation Piles Subjected To Lateral Earth Pressure ? SynopsisBy T. Matsui
Many existing bridge abutments on the soft ground laterally move and their many damage examples have been reported. An essential cause for the troubles of the lateral movements may be the lack of exam
Jan 1, 2010
-
Static Behavior Of Single Piles Subjected To Repeated And Reciprocating Loadings ? SynopsisBy L. Z. Xie
The results of the experimental study on the static behavior of single piles subjected to repeated and reciprocating axial loadings are recommended in this paper. Tests of four full-scale single piles
Jan 1, 2010
-
Pile Foundations In Liquefiable Soils - A Case Study - SynopsisBy R. K. M. Bhandari
Geotechnical investigation for a LPG plant located in Assam state - an area of high seisimicty - revealed a layer of loose to medium silty sand susceptible to liquefaction at some depth below the fini
Jan 1, 1996
-
Underpinning Of A 16th Century Cistercian Abbey FoundationBy Michel Bustamante
The original Cistercian Lure abbey situated in eastern France and built in the second half of the 16th century, has become nowadays an administrative building. Because it has been founded on poor grou
Jan 1, 2002
-
Helical Piles With Grouted Shafts - A Case HistoryBy Shawn Downey
A helical pile with in-situ grouted shaft was used to underpin the existing slab of a large retail store in the Edmonton, Alberta Canada area. The existing structural slab did not have the capacity to
Jan 1, 2003
-
Effect Of Curing Stresses On The Mechanical Properties Of Soil-cement Mixed MaterialsBy George Onorato, Giovanni Bonita
Deep soil mixing (DSM) has now become a ubiquitous ground improvement technique across the globe for producing soil-cementous materials for many types of complex civil and environmental applications.
-
Field Tests Of Soft Clay Stabilized By Stone Columns In Coastal Areas In China (325b7cc0-aff5-4a88-9f69-cd3dc2f57f1d)By Han Jie
The results of full scale plate load tests on stone columns on soft clay in coastal areas are presented in this paper. Four load tests were made, two of which were performed on the ground treated with
Jan 1, 1991
-
Time Effect Of Bearing Behavior Of Bored Pile Group In Un-Saturated Silty Soil ? SynopsisBy J. L. Liu
Long-term maintained load test on the bored pile group in unsaturated silty soil has been carried out. And the research on the time effects of bearing behavior of pile group has been done by the metho
Jan 1, 2010
-
Numerical Analysis Of The Pile-Enhanced Raft Of The Queen Elizabeth II Conference Centre In London, UKBy Trevor I. Addenbrooke
Stress reducing piles were used for the first time at the Queen Elizabeth II Conference Centre near the Palace of Westminster in London, UK. The inclusion of these piles directly beneath heavily loade
Jan 1, 2002
-
Lessons Learned From Mitigating Early Project Delays To Deep Foundation WorkBy Jeffery L. Ottesen
Early construction delays can jeopardize timely completion of subsequent work. As an early construction activity, and due to many unforeseen issues, deep foundation work inherently bears great potenti
Jan 1, 2002
-
Structure Monitoring During UnderpinningBy Barry C. Roth
A Real Time Automated Remote Reading Electrolytic Tilt Monitoring System was effectively deployed for monitoring an existing five story brick building during underpinning, shoring and excavation opera
Jan 1, 2007
-
On The Ultimate Capacity And Radial Stress Distribution Of Driven Piles In SandsBy E. Ulrich Klotz
It is difficult to predict accurately the capacity of driven piles in sand. In practice, this uncertainty either leads to conservative designs if the capacity is under-predicted, or worse, if the cap
Jan 1, 2002
-
Diameter Effects On p-y CurvesBy Ignatius P. O. Lam
This paper presents information on design analyses of large diameter piles using conventional p-y curves as recommended by the American Petroleum Institute (API RP2A, 1993). API RP2A adopted the soft
Jan 1, 2013