Technical Papers and Discussions - Physical Metallurgy - Metallography with the Electron Microscope (Metals Technology,

- Organization:
- The American Institute of Mining, Metallurgical, and Petroleum Engineers
- Pages:
- 20
- File Size:
- 3430 KB
- Publication Date:
- Jan 1, 1944
Abstract
This paper is a progress report covering metallographic applications of the electron microscope that have been made during the past year at Carnegie Institute of Technology. An account is presented of the techniques that have been most satisfactory, the difficulties encountered, the resolution obtained, and the peculiarities that have been noted in the microstruc-tures. About 1200 exposures have been made during the year on the instrument, which is an RCA type B2 transmission microscope,' and a number of these have been selected to illustrate the results obtained. prints are also included showing the common types of falsities—to borrow a term from the biological field, the "artifacts." ln brief, the paper is a record of our attempt to determine the value of the electron microscope in the study of the structure of metals and alloys. In addition to comments on techniques and the quality of photomicrographs obtainable with them, the paper discusses the nature of the etch attack on a few metals, and the possible relation between the fine structure revealed by etching and the mosaic block structure of the grains, since numerous papers and reviews are available on the subject of imperfection in crystals, the comments here may be very brief; in fact, are restricted almost entirely to points having to do with recent theories relating the strength of metals to imperfections and to spacings of slip lines. Specimen Preparation and Photographs Mechanical polishing by hand was used throughout this work. Precautions that must be taken in microscopy at high magnification, which have been well explained by Vilella in his book on Metallographic Technique for Steel, are likewise important with the electron microscope. This applies particularly to the need for these polishing and etching (each successive polish becoming less severe and each etch lighter), since the fina1 etch should in general be no heavier than is used for oil-immersion optical microscopy and in many instances should be much lighter (compare Figs. 6a and 7a, 6d and 7b). An extremely light etch, of course, is incapable of cutting through a flowed layer of appreciable thickness. Unquestionably it would be very advantageous in each instance to compare the structures obtained by electrolytic polishing with those obtained by mechanical polishing, but difficulties with the electrolytic method have prevented this in the following collection of prints. The choice of etchant is important, of course; for example, picral proved superior to nital for tempered martensite. With the exception of Figs. Ib and 16, the replicas used were of silica, deposited upon polystyrene and floated from the polystyrene in ethyl bromide according to the method of Heidenreich and Peck.2 The samples were mounted in Bakelite, polished and etched, then the polished Bakelite
Citation
APA:
(1944) Technical Papers and Discussions - Physical Metallurgy - Metallography with the Electron Microscope (Metals Technology,MLA: Technical Papers and Discussions - Physical Metallurgy - Metallography with the Electron Microscope (Metals Technology,. The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1944.