RI 7625 Flame Spread Evaluation Of Ventilation Cloth
    
    - Organization:
 - The National Institute for Occupational Safety and Health (NIOSH)
 - Pages:
 - 12
 - File Size:
 - 3333 KB
 - Publication Date:
 - Jan 1, 1972
 
Abstract
Comparative data from ASTM method of test E-162 and large-scale trials in the Experimental Mine show that the flame-spread quality of brattice cloth and other ventilation control materials can effectively be evaluated by either method.     Materials having a flame spread index of 25 or less, as determined by the simpler and more economical laboratory test ASTM E-162, do not present a serious fire hazard when used in coal mines.
Citation
APA: (1972) RI 7625 Flame Spread Evaluation Of Ventilation Cloth
MLA: RI 7625 Flame Spread Evaluation Of Ventilation Cloth. The National Institute for Occupational Safety and Health (NIOSH), 1972.