Papers - Research on Coal for Domestic Stokers (T. P. 1448, with discussion)

- Organization:
- The American Institute of Mining, Metallurgical, and Petroleum Engineers
- Pages:
- 16
- File Size:
- 947 KB
- Publication Date:
- Jan 1, 1942
Abstract
In 1939, at the request of The Koppers Coal Co., the Koppers Company Research Department established a Stoker Coal Research Laboratory for the purpose of investigating the performance characteristics of stoker coals in typical domestic stoker installations. Fig. I is a photograph of part of the laboratory. The material in this paper deals with the performance of one coal in a single installation. Presented are details of this installation, mechanical characteristics of the stoker, and the results of a series of burning tests in which adjustments were systematically varied. Summary OF Results Mechanical Features I. A large percentage of the total power consumed by a domestic stoker is used to operate the gear case and motor (Fig. 3)- 2' The power consumption per ton goes down with an increase in rate of coal feed (Fig. 4). 3. The automatic air control in this stoker showed advantages Over manual control (Fig. 5). 4. The air velocities through the retort tuyeres were uniform around the retort, but varied between the rows of tuyere rings (Fig. 6). 5. The crushing of coal with this stoker increased the minus 1/8-in. from 11.6 per cent to 19.2 per cent. There was a notice- able segregation of coal as it came from the retort and distribution was not uniform (Fig. 7). 6. Measurement of air entering over the fire showed that with some not uncommon adjustments this air may be a high percentage of the total air supply (Fig. 8 and Table I). Operating Performance ,. The, removal of clinker was shown to give a period of poor performance characterized by a high fuel-bed resistance and a high percentage of carbon monoxide in the flue gases (Fig. 10). 2. The fuel-bed resistance was found to decrease as the fuel bed built up in a normal response to heat demand after a prolonged hold-fire (Fig. II). 3. with intermittent operation the burning rate was almost always less than the feeding rate, The wide variations were found to be greatly dependent upon the length of the On period and the length of the intervals between On periods (Fig. 12). 4. The maintenance of a low furnace draft led to less fly ash, better clinker formation, and higher efficiencies (Fig. 13). 5. The maintenance of a minimum of excess air also resulted in less fly ash, better clinker formation, and higher efficiencies (Fig. 14). Guiding Principles In planning the investigations, the following principles were adopted: Selection of Heating Equipment.—Use only standard models of stokers and furnaces representative of those widely used.
Citation
APA:
(1942) Papers - Research on Coal for Domestic Stokers (T. P. 1448, with discussion)MLA: Papers - Research on Coal for Domestic Stokers (T. P. 1448, with discussion). The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1942.