IC 9306 - Motor Monitoring System For A Continuous Miner
    
    - Organization:
 - The National Institute for Occupational Safety and Health (NIOSH)
 - Pages:
 - 16
 - File Size:
 - 2436 KB
 - Publication Date:
 - Jan 1, 1992
 
Abstract
The U.S. Bureau of Mines has investigated the early detection of insulation failure in squirrel cage induction motors for the past 4 years. Research was done using a sophisticated empirical data-modeling technique based on values calculated from a motor's voltage and current phasors. This technique produces two polynomial equations that calculate the insulation leakage current and power. These models were implemented in a prototype system that monitors six motors on a continuous miner for insulation leakage. These insulation leakage values are used to anticipate insulation failure.  The system consists of a motor-data-system for each motor on the machine and a control computer located away from the miner. Each motor-data-system consists of an analog interface to the motor's voltages and currents, a single-board computer that reads digitized data and calculates voltage and current phasors, and a bus node that interfaces the single-board computer with the rest of the system by way of a serial bus system. Using this bus system, the control computer requests and receives phasor data from the motor-data-systems.  From these data the control computer calculates and displays two deterioration values for each motor, for leakage current and power, using Bureau-developed models. These values are stored in a data base from which the user can display graphs of each motor's deterioration values over time.
Citation
APA: (1992) IC 9306 - Motor Monitoring System For A Continuous Miner
MLA: IC 9306 - Motor Monitoring System For A Continuous Miner. The National Institute for Occupational Safety and Health (NIOSH), 1992.