Design Criteria For Uranium Ion Exchange In A Fluid System

Society for Mining, Metallurgy & Exploration
D. E. Traut
Organization:
Society for Mining, Metallurgy & Exploration
Pages:
19
File Size:
2030 KB
Publication Date:
Jan 1, 1975

Abstract

A fluidized countercurrent ion-exchange system was developed, operated, and evaluated by the Bureau of Mines. The system consisted of integrated multiple-compartment absorption and elution columns in which the solution flows are continuous except for short periods when resin increments are withdrawn. The exchange of uranyl sulfate between a simulated acid leach uranium solution and a strong-base, ion-exchange resin together with the subsequent elution with an acidified sodium chloride solution was studied. The effects of the number of sections, section heights, amount of resin withdrawal, and solution flow rates were investigated. Also examined were the kinetic and equilibrium relationships for the absorption step. The experimental data indicate a strong interdependence between variables. Solution retention time appears to be a major limiting variable. The column was efficient over a range of conditions, but close control was needed for optimum operation.
Citation

APA: D. E. Traut  (1975)  Design Criteria For Uranium Ion Exchange In A Fluid System

MLA: D. E. Traut Design Criteria For Uranium Ion Exchange In A Fluid System. Society for Mining, Metallurgy & Exploration, 1975.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account