Case History: Use of Vibro-Replacement Stone Columns for both Liquefaction Mitigation and to Improve Static Settlement

Deep Foundations Institute
Martin Hudson Lisheng Shao Adam Richardson Navid Plaseied
Organization:
Deep Foundations Institute
Pages:
9
File Size:
1013 KB
Publication Date:
Oct 31, 2023

Abstract

At a project site in San Diego, California, the hazards of liquefaction and seismically-induced settlement were present, in conjunction with relatively compressible soils that would require a low bearing value for use of spread footings. In addition, the site had variable conditions such that a portion of the site did not exhibit such hazards. Therefore, vibro-replacement stone column ground improvement was chosen to be performed such that the multiple hazards would be mitigated, allowing for use of spread footing foundations for a new building throughout the site. The post-improvement seismic performance of the soils beneath footings was calculated and served as the basis for seismic design for the vibro-stone columns. The post-improvement static performance of the soils beneath footings was evaluated using a modulus test in the field. The results of the modulus test confirmed the design assumptions regarding static settlement. The construction techniques are discussed herein, as are the testing and calculations used to justify the mitigated hazards and compliance with the design criteria.
Citation

APA: Martin Hudson Lisheng Shao Adam Richardson Navid Plaseied  (2023)  Case History: Use of Vibro-Replacement Stone Columns for both Liquefaction Mitigation and to Improve Static Settlement

MLA: Martin Hudson Lisheng Shao Adam Richardson Navid Plaseied Case History: Use of Vibro-Replacement Stone Columns for both Liquefaction Mitigation and to Improve Static Settlement. Deep Foundations Institute, 2023.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account